High Speed Differential Counter/Timer Board

DNx-CT-602, DNA-CT-602, DNR-CT-602, DNF-CT-602

Features

  • 4 independent 32-bit counter/timer units
  • Fully differential inputs/outputs at RS-422/485 logic levels
  • 8 Counting modes
  • 32-bit prescaler per channel
  • Internal (66 MHz) or external (max 16.5 MHz) timebases
  • 256 x 32-bit Input FIFO and 256 x 32-bit Output FIFO on each counter
  • Debouncing/glitch removal on external clock and gate inputs
High Speed Differential Counter/Timer Board
Product Style: What do the "DNx" prefixes mean? "DNA" prefix is for a Cube & MIL Cube Board, "DNR" prefix is for a Rack & MIL Rack Board , and "DNF" prefix is for a FLATRACK board.
Software/Programming: How UEI solutions are used. Hosted - Connected to a PC with Windows, Linux, QNX, VxWorks, RTX, or similar OS. Hosted also is for OPC-UA, Modbus and EtherCAT. Standalone - Controller with Linux or VxWorks OS, Simulink I/O Target or UEILogger. Available options for this product are shown in the drop down menu.
Quantity: $1260
Add to Cart

Typically in stock for shipment in 3-4 weeks. Subject to global supply chain challenges.

DNx-CT-602, DNA-CT-602, DNR-CT-602, DNF-CT-602

The DNx-CT-602 board is a differential counter/timer interface that provides four independent 32-bit channels, each one having overvoltage protection and optoisolation. They can act as an event counter, perform width/ period measurements and run in quadrature-encoder mode where the user sets the direction of the counting. For output modes, the layer offers 1-shot and Universal PWM operation. It also provides edge detection on the ClockIn and Gate pins. The DNx-CT-602 is software compatible with the DNx-CT-601 except for additional commands, which configure and control the Trigger output pins.

The DNx-CT-602 provides the following 8 counting modes which will accommodate most data acquisition and data logging requirements:

  • Timer
  • PWM generator
  • Continuously updated PWM generator (buffered)
  • Bin counter (number of pulses in specified time interval)
  • Pulse width
  • Pulse period (232 periods max)
  • Quadrature encoder
  • Timebase operation